i.Node series -The i.Node series products are network I/O devices that have adopted the LonWorks flatform (ANSI/EIA/CEA 709.1) and are used exclusively for LonWorks that is a standard for the open distributed control in the industrial automation control sector.

LonWorks-based controlling network can be built by connecting various digital and analog sensors and actuators to the iNode series products, receiving values from the sensors, and controlling the actuators. <<
i.Node PDI8
 
Product Features
  Provides Digital Inpu 8ch The system¡¯s stability and scalability have been enhanced due to the intelligent distributed control method
  Easy to install and maintain as the system is based on a network. Interactive communication, multi-targeting and multi-controlling are made possible
  Digitalized I/O processing due to intelligent devices Easy to install and manage due to the LNS plug-in program. A user interface is supported.
Product Specifications

Item

Description

Processor Type

PL3150

Transceiver Type

Processor Clock

10MHz

Memory

AT29C512(32K Flash Memory)

Comm. Media

PLC(Power Line Communication)

POWER

100~240 VAC, 50/60Hz

Protocol

ANSI/EIA/CEA 709.1 Lon Talk Protocol,
ANSI/EIA/CEA 709.2 Power Line

Digital Input

Dry-contact, 30VDC Max (0~9V:ON, 9~ :OFF)

Dimension

92(W) x 96(H) x 82(D) mm

Operation

-10~50¡É, 0~85%

Temp./Humidity

Mounting

Wall mount type or Din Rail Base Plate type

Plug-in

Plig-In type

Functions

Digital Input

Select among the digital input detection functions: Direct, One shot, Togle, Pulsed, Override

Digital Output

Set the digital output control functions: Direct, One shot, Togle, PWM, One pulse, Preset, Override

Analog Input

Select among the analog input detection functions : Sensor type and range setting, Filter setting, NV range & offset setting

User table setting, Upper limit/Lower limit alarm setting, Override

Analog Outpt

Set the digital output control functions: Preset table, Input range setting, Scaling, Offset, Override

Loop

Set the PID control function: P/I/D factor setting, and P_bias, Deadband, and I limit setting

Compare

Input NV comparison function: Equal, Not Equal, Greater than equal, Less, And, Or, Or not

Multi Function

Input NV comparison and operation functions: Logic, Encoder, Counter, On time, And, And not, Or, Or not, Equal

Not equal,Greater than equal,Less,Selector,Higher,lower,Add

Sub,Mul,Div,Enthalpy

Analog Control

Input NV comparison and operation functions: Equal, Not equal, Greater than equal, Less, Select, Higher, lower

And,Andnot,Or,Ornot,Enthalpy,And,Sub,Mul,Div,Output NV scaling

Digital Control

Logic, Encoder, On time, and Counter functions based on Input NV

General Function Block
  
General Function Block
  
 
  
 
   HEAD OFFICE : 159, Sayeon-gil, Beomseo-eup, Ulju-gun, Ulsan, Republic of Korea
   Tel : +82-25-254-3470~3 / FAX : +82-52-254-3456
   COPYRIGHT(C) 2011 BY ADIC.CO.,LTD ALL RIGHTS RESERVED.